All Categories
Your shopping cart is empty!
Plates
Indication: Used for pseudarthrosis of the humerus and as a tension band plate for femoral fractures. Not for use on the tibia. The MC-DCP holes allow compression in both directions of the longitudinal axis. MC-DCP: Minimal contact dynamic compression plate...
$0.00
Indication: Used as a neutralisation and tension band plate for fractures of forearm, humerus and tibia. Not for use on the femur. The MC-DCP holes allow compression in both directions of the longitudinal axis. MC-DCP: Minimal contact dynamic compression plate...
Indication: Used for smaller bones particularly ulna and radius. The MC-DCP holes allow compression in both directions of the longitudinal axis. MC-DCP: Minimal contact dynamic compression plate..
Indication: Used for the lengthening osteotomies of the femur. Slot for articulated tension device for distraction or compression..
Indication: Used for pseudarthrosis of humerus and as a tension band plate for femoral fractures. Not for use on the tibia. Compression is achieved by use tension device. ..
Indication:Used as neutralization and tension band plates for fractures of forearm, humerus and tibia. Compression achieved through the use of the tension device. ..
Indication: Used for smaller bones particularly ulna and radius. Compression achieved through individual hole design, in which engagement between the spherical undersurface of screw head and sloping base of the elongated screw hole, creates relatively movement between bone and plate in the di..
Indication: Used for smaller bones particularly ulna and radius. Compression achieved through individual hole design, in which engagement between the spherical undersurface of screw head and sloping base of the elongated screw hole, creates relatively movement between bone and plate in the ..
Indication: Primary indicated for areas of low stress such as recommended for the fractures of fibula. Compression is applied by eccentric positioning of the screw against the side of the screw hole furthest from the fracture line. ..
Indication: Used as buttress plate for fibula, metatarsals, and metacarpals bones. Compression is applied by eccentric positioning of the screw against the side of the screw hole furthest from the fracture line. ..
Indication: Used for maxillofacial surgery, hand and foot surgery. Compression is achieved through individual hole design, in which engagement between the spherical undersurface of the screw head and sloping base of elongated screw hole, creates relative movement between bone and plate in t..
Indication: Used principally in the reconstruction of the pelvis. The design of these plates allows for three dimensional contouring. Due to their reduced stiffness, they should only be used for tension-band fixation or adaption. ..
Indication: Used principally in the reconstruction of the pelvis. The design of these plates allows for three dimensional contouring. Due to their reduced stiffness, they should only be used for tension-band fixation or adaption...
Indication: Used principally in the reconstruction of the pelvis. It is slightly thicker than the straight pelvic reconstruction plate and prevent for the pelvic crest. ..
Indication: Used principally in the treatment of pelvic, clavicle and calcaneal fractures. The design of these plates allows for three dimensional contouring. Due to their reduced stiffness, they should be used only for cerclage or adaptations. ..
Indication: Indicate primarlly in comminuted fractures of smaller diameter bones specially used for mandibular reconstruction surgery. The design of these plates allows for three dimensional contouring. ..
Indication: Used to treat comminuted fractures, particularly of the distal humerus. The design of these plates allows for three-dimensional contouring. ..
Indication: Used to treat comminuted distal humerus intra-articular or extra-articular fractures. Depending on the fracture configuration like T or Y type, the plates are shaped to be placed according to the anatomy of proximal humerus. The pre-formed shape of the plate requires that a sep..
Indication: The epicondylar humerus plates have been designed to be used for the distal fractures of humerus. Particularly can be indicate for multi-fragmented fracture of distal humerus joint, according to the anatomy of medial and lateral epicon-dyle. The pre-formed shape of the plate re..
Indication: The humerus T plates have been designed to be used for proximal humerus fractures. Design for both left and right side. The various configuration of T plate allow for anatomic reduction and alternative screw placement. ..
Indication: The proximal humerus plates have been designed to be used for proximal humerus fractures. Particularly the shape of this plate permit a stable fixation of two part surgical neck fracture. Head of plate with left and right variation allow anatomic reduction and alternative screw ..
Indication: The spoon plate is a buttress plate designed to sit on the anterior crest of the tibia. It is primary indicated for pilon fractures that have extensive anterior crushing but good posture support.It is also used in the treatment of metaphyseal non-unions of distal tibia and the ..
Indication: The T plate is primary used as a buttress plate for medial tibial plateau. It is also used in the distal tibia, medial distal femur and A3 fractures of proximal humerus. It is relatively thin and consequently not as strong as standard self compressing plate. It is designed to be ..
Indication: The L plate is an adaptation of a standard T plate. All holes configurations and plate dimensions are similar to that of the standard T plate, but the head of the plate is shifted either left or right to allow for alternative screw placement. recommended for treatment of tibial..
Indication: The L buttress plate is an adaptation of a standard T buttress plate. All holes configurations and plate dimensions are similar to that of the standard T buttress plate, but the head of the plate is shifted either left or right to allow for alternative screw placement. The double..
Indication: The cloverleaf plate is a buttress plate designed to sit on the medial aspect of the distal tibia. It is thin and can be easily cut. The plate has a frontal wing which allows fixation to the medial malleous. The plate can also be modified by having this frontal wing cut of which ..
Indication: Used to treat distal radius fractures. Designed for both left and right side. The various configurations of T-plate allow for anatomic reduction. ..
Indication: sed to treat distal radius fractures. It can be used for left and right radius. The various configurations of T-plate allow for anatomic reduction..
Indication: To be used in stabilizing for head of interlingual articulation of hand. Plates are slightly concave with right, left and oblique (T-shaped) end hole style. ..
Indication: Used to treat small bone fractures, e.g metatarsals and metacarpals. Compression is applied by eccentric positioning of the screw against the side of the screw hole furthest from the fracture line. ..
Indication: The cervical spine H plate is principally used for spine arthrode-ses also for calcaneus. ..
Indication: Used for stabilization and osteoarthritis in anterior surgery of the cervical. ..
Indication: The design of the posterior plates comes from spine anatomy. The average distance between two adjacent pedicles is 26 mm. The plates are created with holes every 13 mm. It is therefore possible to fix two adjacent vertebrae with a perpendicular screw every two holes. The plates..
Indication: Used when an arthrodesis of the hip is to be performed. 6.5 mm cancellous screws are used through the proximal fixation holes into the femoral head. The plate is then secured to the femoral shaft with 4.5 mm cortical screws...
Indication: The condylar buttress plate have been designed to be used for the fractures of distal femur. They come in a right and a left version. They are heavier and stronger than all other buttress plates since they have to witstand much greater forces. ..
Indication: The lateral tibial head plate is designed as a buttress plate of the lateral tibial plateau. Available with various holes. The head of this plate is shifted either left or right to allows for alternative screws placement. ..
Indication: Anatomical distal tibia bone plates are designed to be used for reducing fractures of the distal tibia.It is designed to sit on the distal aspect of the tibia The anatomical bone plate features show the following important factors to osteo-synthesis as; permit a stable fixation o..
Indication: Anatomical lateral proximal tibia bone plates are designed to be used for reducing fractures of the proximal tibia. These plates are indicated where the shape of the fracture or the soft tissue problems do not make plate attachment to the medial tibial surface advisable.It is des..
Indication: Anatomical distal femur bone plates are designed to be used for reducing fractures of the distal femur with or without involvement of the joint. The anatomical bone plate features show the following important factors to osteosynthesis as; permit a stable fixation of the small p..
Indication: Anatomical proximal femur bone plates are designed to be used for reducing fractures of the proximal femur with or without involvement of the joint. The anatomical bone plate features show the following important factors to osteo-synthesis as; permit a stable fixation of t..
Indication: To be used in fixation of fractures in small bones primarly for finger joint head and foot. ..